A thermal zone tells you which climate a manufactured home was insulated for. The federal standard splits the country into three, numbered 1 to 3 from warmest to coldest. A home built for a colder zone must lose less heat through its floor, walls, roof and windows.

Data as of 2026-11-27

How the standard measures insulation

The three zones come from 24 CFR 3280.506, the heat loss section of the federal construction standard. The rule calls them Uo value zones. Uo is one number for how quickly heat passes through the whole outer shell of the home: floor, walls, ceiling, windows and doors counted together.

A lower Uo means less heat escapes. The most each zone allows is:

  • Zone 1: 0.116
  • Zone 2: 0.096
  • Zone 3: 0.079

The unit is Btu per hour, per square foot of shell, per degree Fahrenheit of difference between indoors and outdoors.

The section does not set an R-value for each wall or ceiling. It limits the total, and it requires insulation in every exterior wall, floor and ceiling cavity. One more thing is fixed: a Zone 3 home must leave the factory with storm windows or insulating glass.

Which zone is which

The rule shows the zones on a map of the United States. In broad terms, Zone 1 is the warmest part of the South, Zone 3 is the cold northern states, and Zone 2 lies between them. Read the map itself for your state instead of guessing; a copy comes with every home.

Finding it in the home

Each home has a heating certificate fixed to an inside surface where the occupant can see it. The certificate names the zone the home was insulated for, includes the zone map, and gives the lowest outdoor temperature at which the installed furnace can hold the home at 70 degrees Fahrenheit.

Factories may combine this certificate with the data plate, which also shows the wind and roof load ratings. Both are usually found beside the electrical panel, in a kitchen cabinet or in a bedroom closet.

Why it limits where a home can go

The federal installation standards say a home must not be installed in a zone that exceeds the one it was designed for. A Zone 1 home cannot be set up where Zone 3 applies. A Zone 3 home can go in any of the three, because it already beats what the warmer zones ask.

So one of the first things to check on a floor plan is its thermal zone. Manufactured home factories tend to build for the regions they ship to, and a plant in a warm state may not offer a Zone 3 package at all.

Treat the zone as a legal minimum and not as a promise of low bills. If running costs matter to you, compare the insulation and window options plan by plan, and look at our ENERGY STAR homes, which are built to that program's requirements on top of the federal minimum. Our double-wide homes are a good place to start comparing.

FLOOR PLANS

Homes to look at

Real floor plans from Lakin Homes, each with photos, a floor plan and its price on the home page.

Common questions

Can I put a Zone 2 home in a Zone 3 state?

No. The installation standards do not allow a home in a colder zone than the one it was insulated for. You would need the same plan built to Zone 3, if the factory offers it.

Is the zone number an R-value?

No. It stands for a limit on heat loss through the whole shell of the home, called the Uo value. R-values describe single layers of insulation. Two homes in the same zone can use different R-values in the floor, walls and roof and both meet the limit.

Does a higher zone number mean a warmer home?

It means a better insulated one. Zone 3 allows the least heat loss and Zone 1 the most, so the higher number suits a colder climate.

FLOOR PLANS

More floor plans

Every home has its own page with photos, specifications and price.

Your next step

Compare floor plans and ask the factory which insulation zone each one is built for.